Search results for "Automated perimetry"
showing 4 items of 4 documents
Structure-function relationship between FDF, FDT, SAP, and scanning laser ophthalmoscopy in glaucoma patients.
2012
Purpose Flicker defined form perimetry (FDF) and frequency doubling technology perimetry (FDT) are alleged to detect glaucoma at an earlier stage than standard automated perimetry (SAP). It is the purpose of this study to investigate the structure-function relationship between FDF, FDT, SAP, and confocal scanning laser ophthalmoscopy (cSLO) in patients with glaucoma. Methods Seventy-six patients with glaucoma were included in the study. Patients were tested with SAP, Matrix-FDT, FDF perimetry, and cSLO. Structure-function relationships between global and sectoral cSLO parameters and global and sectoral mean sensitivity (MS) of SAP, Matrix-FDT, and FDF were calculated using Spearman's rank c…
Blue-yellow deficiencies in young moderate smokers.
2021
Purpose To evaluate whether tobacco affects color vision in young moderate smokers. Methods Chromatic mechanisms of 13 moderate smokers (10–20 cigarettes/day and at least 5 years smoking) and 17 non-smokers in the 18–35 age range were assessed with the Farnsworth-Munsell 100-hue (FM100h) test and short wavelength automated perimetry (SWAP). Results FM100h Total Error Scores (TES) were higher for smokers, and although differences were not significant (p = 0.14), a linear model with principal component analysis was able to explain 95% of the variance in TES and red-green partial error scores, though not in blue-yellow partial error scores (p = 0.07), using the number of years as smokers and t…
Effect of Multizone Refractive Multifocal Contact Lenses on Standard Automated Perimetry
2012
PURPOSE The aim of this study was to evaluate whether the creation of 2 foci (distance and near) provided by multizone refractive multifocal contact lenses (CLs) for presbyopia correction affects the measurements on Humphreys 24-2 Swedish interactive threshold algorithm (SITA) standard automated perimetry (SAP). METHODS In this crossover study, 30 subjects were fitted in random order with either a multifocal CL or a monofocal CL. After 1 month, a Humphrey 24-2 SITA standard strategy was performed. The visual field global indices (the mean deviation [MD] and pattern standard deviation [PSD]), reliability indices, test duration, and number of depressed points deviating at P<5%, P<2%, P<1%, an…
Optical quality of hyperopic and myopic phakic intraocular lenses
2013
Aims: To assess and compare the optical quality of the myopic and hyperopic implantable collamer lens (ICL) from its wavefront aberrations for different powers and pupil diameters. Settings and Design: Prospective study. Material and Methods: The wavefront aberrations of two myopic (−3 and −6 diopters (D)) and two hyperopic V4b ICLs (+3 and +6D) were measured in vitro . To assess and compare the optical quality of different powers of ICLs, we analyzed the root mean square (RMS) of total higher order aberrations (HOAs), trefoil, coma, tetrafoil, secondary astigmatism, and spherical aberration at 3- and 4.5-mm pupil. In addition, the point spread functions (PSFs) of each ICL evaluated were ca…